hpacucli es társainak telepítése:
/etc/apt/sources.list-be:
deb http://downloads.linux.hp.com/SDR/downloads/ProLiantSupportPack/Ubuntu oneiric current/non-free
valamelyik észlény úgy gondolta, hogy jó vicc az ubuntut Ubuntura cserélni...
kulcs letöltése:
wget http://downloads.linux.hp.com/SDR/downloads/ProLiantSupportPack/GPG-KEY-ProLiantSupportPack -O - | apt-key add -
hpacucli használata:
.. TODO: Indent lines, set language: Example .. code-block:: python setarch x86_64 --uname-2.6 /usr/sbin/hpacucli
hpacucli ctrl slot=3 ld all show detail // cloud-on igy kell megnezni a diszkeket hpacucli ctrl slot=3 pd all show detail // cloud-on igy kell megnezni a diszkeket ctrl all show config detail
ctrl sn=P92CB0BMQRO02Q modify drivewritecache=enable ctrl sn=P92CB0BMQRO02Q physicaldrive 1:10 modify led=on diszkcsere utan: rescan ctrl sn=P92CB0BMQRO02Q ld 4 modify led=on modify reenable forced
.. TODO: Indent lines, set language: Example .. code-block:: python Linux - hpacucli
This document is a quick cheat sheet on how to use the hpacucli utility to add, delete, identify and repair logical and physical disks on the Smart array 5i plus controller, the server that these commands were tested on was a HP DL380 G3 server with a Smart Array 5i plus controller with 6 x 72GB hot swappable disks, the server had Oracle Enterprise Linux (OEL) installed.
After a fresh install of Linux I downloaded the file hpacucli-8.50-6.0.noarch.rpm (5MB), you may want to download the latest version from HP. Then install using the standard rpm command.
I am not going to list all the commands but here are the most common ones I have used thus far, this document may be updated as I use the utility more.
Utility Keyword abbreviations Abbreviations chassisname = ch controller = ctrl logicaldrive = ld physicaldrive = pd drivewritecache = dwc hpacucli utility hpacucli # hpacucli
hpacucli help
Note: you can use the hpacucli command in a script Controller Commands Display (detailed) hpacucli> ctrl all show config hpacucli> ctrl all show config detail Status hpacucli> ctrl all show status Cache hpacucli> ctrl slot=0 modify dwc=disable hpacucli> ctrl slot=0 modify dwc=enable Rescan hpacucli> rescan
Note: detects newly added devices since the last rescan Physical Drive Commands Display (detailed) hpacucli> ctrl slot=0 pd all show hpacucli> ctrl slot=0 pd 2:3 show detail
Note: you can obtain the slot number by displaying the controller configuration (see above)
Status
hpacucli> ctrl slot=0 pd all show status
hpacucli> ctrl slot=0 pd 2:3 show status
Erase hpacucli> ctrl slot=0 pd 2:3 modify erase
Blink disk LED hpacucli> ctrl slot=0 pd 2:3 modify led=on
hpacucli> ctrl slot=0 pd 2:3 modify led=off
Logical Drive Commands
Display (detailed) hpacucli> ctrl slot=0 ld all show detail <detail>
_
hpacucli> ctrl slot=0 ld 4 show detail <detail>
_
Status hpacucli> ctrl slot=0 ld all show status
hpacucli> ctrl slot=0 ld 4 show status
Blink disk LED hpacucli> ctrl slot=0 ld 4 modify led=on
hpacucli> ctrl slot=0 ld 4 modify led=off
re-enabling failed drive hpacucli> ctrl slot=0 ld 4 modify reenable forced
Create # logical drive - one disk
hpacucli> ctrl slot=0 create type=ld drives=1:12 raid=0
logical drive - mirrored
hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14 size=300 raid=1
logical drive - raid 5
hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14,1:15,1:16,1:17 raid=5
Note: drives - specific drives, all drives or unassigned drives size - size of the logical drive in MB raid - type of raid 0, 1 , 1+0 and 5 Remove hpacucli> ctrl slot=0 ld 4 delete Expanding hpacucli> ctrl slot=0 ld 4 add drives=2:3 Extending hpacucli> ctrl slot=0 ld 4 modify size=500 forced Spare hpacucli> ctrl slot=0 array all add spares=1:5,1:7